home
***
CD-ROM
|
disk
|
FTP
|
other
***
search
/
PCMania 75
/
PCMania CD75_1.iso
/
sharewar
/
utiles
/
lock
/
Readme.txt
< prev
next >
Wrap
Text File
|
1998-11-08
|
9KB
|
261 lines
The Lock version 4.98.1108 (The Lock 98)
Complete system security solution for Windows 95
and Windows 98 workstations.
*********************** INFORMATION ************************
*********************** INFORMATION ************************
*********************** INFORMATION ************************
----------------------------------------------------------
INSTALL:
Unzip all files to a temp directory and run INSTALL.EXE
KEY DISK CREATION:
During install, you will be prompted to create a Key Disk.
This feature is also an option from the Admin menu when you
right click on the Padlock icon in the system tray. Creating
this disk will allow access to The Lock for DOS in Admin
mode or The Lock for Windows 95 in Admin Mode by typing
\keydisk as your password at the prompt for The Lock for
DOS or Win95/98. This disk will allow full access to the
system so keep it in a safe place.
BOOT DISK CREATION: You should create a boot disk in the
event that you cannot access your system in the normal
fashion.
To create a boot disk:
Get a blank 3.5 inch floppy disk, mark it "Boot Disk"
Click the Win95 Start Button, or press the Windows Key
Select Settings from the Windows 95 Start Menu
Select Control Panel
Click the Add/Remove programs Icon.
Add/Remove Programs window, select the Startup Disk tab
Click the Create Disk button, follow the prompts.
----------------------------------------------------------
Quick start information listed at the bottom of this
file.
The users manual is now included in Acrobat Reader PDF
format. Point your web browser to the following
address to download the latest version of Acrobat
Reader from Adobe.
http://www.adobe.com/prodindex/acrobat/readstep.html
*********************** INFORMATION ************************
*********************** INFORMATION ************************
*********************** INFORMATION ************************
This program is written in 32-bit Delphi for and designed
for Windows 95 and Windows 95 OSR2.
Software Status: Shareware
Registration Fee: $25 (internet version, no disks no docs)
On-Line Purchase: (Credit Card):
http://www.crashcoursesoftware.com/purchase.htm
Snail-mail purchase: (For checks only):
Mail the following:
Desired Registration Name
Right click the Pad Lock icon, select Register
RegistrationID code from the registration page
your Email address
the registration fee
any comments
to:
CrashCourse Software
PO Box 54321
Oklahoma City, OK 73154-0321
Office: 405-715-9998
Mobile: 405-747-5507 (Emergency only please)
Other Registration Fees:
$10 added for software on floppy disks.
$15 added for software on floppy disks and documentation.
$25 added for software on CD Install and documentation.
Email:
crashcourse@crashcoursesoftware.com
Ash@ionet.net
ICQ: 2726911
http://www.crashcoursesoftware.com
http://www.theknow.com/CrashCourse
The Lock Copyright ⌐ 1996-1998 CrashCourse Software
Parts Copyright ⌐ 1997-98 by Martin Djernµs
============================================================
Features:
* Idle timer watches both Windows and MS DOS boxes
* Admin access on all modes with admin ID and password
* Password authentication via:
- local password file
- Windows 95/98 login password
- Novell Netware 3.12 / 4.1x NDS and Bindery
- Windows NT
- CrashCourse Network Validator (on WinNT or Win95/98)
+When a network server validates the users password,
there is no need to configure the username and password
locally
* Simple Lock Mode for single user and one password
* Multiple user support
- User Profile database allows users to have different
security privileges.
- 90 security levels (Groups) are available each can have
unlimited users.
- Supports local or network modes for user profile storage.
* Group Level Security Profile
- Specify security settings for users including:
+Available Programs to run
+Restricted Programs
+Folder and File access writes (read-only or no-access)
+Custom Start Menu
+Custom Desktop
+Login time restrictions
+Many standard Windows 95/98 system policies (Disable key
control panel options, My Computer, Recycle Bin, etc)
* Activity logs
- Log user access violation attempts
- Create and audit log of all programs and windows a user runs
or opens.
* Network features
- Freeware Network Tools
+Monitor systems on the network running The Lock.
+Create a network image of a Lock install for easy loading onto
another workstation on the network.
+Automatic update of The Lock on a workstation via a Novell
Netware login script
* Wizards for standard configuration and multiple user configuration
* Standardized configuration import and export utility for easy
transport of configuration from one system to another
* Hotkey support for commonly-used functions
============================================================
Updates
============================================================
4.98.1108
Updated release for The Lock
4.98.1106b
Added Shutdown Windows Option to popup menu for The Lock
4.98.1102b
Visual enhancements
Added new configuration import feature.
4.98.1031b
Visual enhancements
Added Windows 98 security items.
Remote program termination improvement
============================================================
Quick Start
============================================================
Three Wizards have been created for ease of installation
and configuration.
1. When The Lock is first installed, it will
automatically run the Security Wizard.
Each option in the Security wizard is presented with a
detail of what the function does. Follow the prompts
carefully, reading each item completely. At the completion
of this portion, the basic system security issues will have
been covered. When the Finish button is presented, one of
three things may happen.
a) The system will close the Security Wizard, and
The Lock will start.
b) The system will log you off then back on if you
selected to disable CD Auto insert notification.
c) The system will completely restart if you selected
to view the system BIOS settings.
When the system restarts, it will usually display a
message such as "Press DEL to enter CMOS" or "Press F2
for SETUP". Once in CMOS, (BIOS), you will want to
disable booting from the A: drive, and set a password up
for access to the system setup. MAKE SURE YOU CONSULT
YOUR SYSTEM USERS MANUAL BEFORE MAKING ANY CHANGES TO YOU
CMOS. THE CMOS SETTINGS CONTROL ALL THE SYSTEM FUNCTIONS
AND AN INCORRECT SETTING MAY CAUSE THE SYSTEM TO FAIL TO BOOT.
Note: if you have elected to change system settings, the
system will cycle to The Lock for DOS during boot up. At
this point, you do not have any passwords configured. Simply
press the enter key to continue.
2. Once you have run the Security Wizard and the system
has reverted back to The Lock, The Lock will prompt you to
change passwords.
The first password to be set is the standard USER password.
There will be a dialog box containing the user name obtained
from the system. Select a password for this user name and
press Done to continue. This password will log the user
into the system at a general user level, but they will not
have administrator access.
The second password is the administrators password. Since
this is the initial install, the default password of
PassWordCrash will be automatically entered into the Old
password box. Select a new Admin password and enter it into
the New password dialog entry. Verify the password and press
the Set Password button to continue. DO NOT FORGET THIS
PASSWORD, THERE IS NO BACK-DOOR BUILT INTO THE LOCK.
3. After password configuration, The Lock will
automatically restart. It is currently configured for one
user password and one Admin password. When The Lock
starts up, log into the system using the Admin password.
Next, right click on the Pad Lock icon in the System Tray
(next to the clock, opposite the Windows 95 Start Button).
If there is no Pad Lock icon, The Lock is not running.
You may start The Lock by pressing the Start Button, selecting
Programs from the menu, then CrashCourse Software. The Lock
will be an item on that menu.
Right click on the Pad Lock icon and The Locks user menu
will appear. Select Options from the menu list, then select
Configuration. This will bring up the Configuration Utility.
This utility will have a Wizard button at the lower left
hand corner. If it does not have the wizard button, press
the Admin button and log into The Lock using your Admin
password. Follow the prompts in the Configuration Wizard
through to its completion.
If you selected to edit User Group Profiles, The Configuration
Wizard will automatically start the User Profile Utility.
Follow this Wizard as you have for the previous two.
These three wizards can be used to configure most any
setting within The Lock.
For any questions or comments, Email to: ccs@theknow.com
(c)1996-1998
CrashCourse Software